Data and Documentation
Open Data Policy
FAQ
EN
DE
FR
Suchbegriff
Advanced search
Publication
Back to overview
Coronary artery calcium quantification from contrast enhanced CT using gemstone spectral imaging and material decomposition.
Type of publication
Peer-reviewed
Publikationsform
Original article (peer-reviewed)
Publication date
2014
Author
Fuchs Tobias A, Stehli Julia, Dougoud Svetlana, Sah Bert-Ram, Bull Sacha, Clerc Olivier F, Possner Mathias, Buechel Ronny R, Gaemperli Oliver, Kaufmann Philipp A,
Project
Entwicklung einer neuen Hybrid-Bildgebungs-Methode zur nicht invasiven kardialen Diagnostik
Show all
Original article (peer-reviewed)
Journal
The international journal of cardiovascular imaging
Volume (Issue)
30(7)
Page(s)
1399 - 405
Title of proceedings
The international journal of cardiovascular imaging
DOI
10.1007/s10554-014-0474-0
Abstract
To explore the feasibility of coronary artery calcium (CAC) measurement from low-dose contrast enhanced coronary CT angiography (CCTA) as this may obviate the need for an unenhanced CT scan. 52 patients underwent unenhanced cardiac CT and prospectively ECG triggered contrast enhanced CCTA (Discovery HD 750, GE Healthcare, Milwaukee, WI, USA). The latter was acquired in single-source dual-energy mode [gemstone spectral imaging (GSI)]. Virtual unenhanced images were generated from GSI CCTA by monochromatic image reconstruction of 70 keV allowing selective iodine material suppression. CAC scores from virtual unenhanced CT were compared to standard unenhanced CT including a linear regression model. After iodine subtraction from the contrast enhanced CCTA the attenuation in the ascending aorta decreased significantly from 359 ± 61 to 54 ± 8 HU (P < 0.001), the latter comparing well to the value of 64 ± 55 HU found in the standard unenhanced CT (P = ns) confirming successful iodine subtraction. After introducing linear regression formula the mean values for Agatston, Volume and Mass scores of virtual unenhanced CT were 187 ± 321, 72 ± 114 mm(3), and 27 ± 46 mg/cm(3), comparing well to the values from standard unenhanced CT (187 ± 309, 72 ± 110 mm(3), and 27 ± 45 mg/cm(3)) yielding an excellent correlation (r = 0.96, r = 0.96, r = 0.92; P < 0.001). Mean estimated radiation dose revealed 0.83 ± 0.02 mSv from the unenhanced CT and 1.70 ± 0.53 mSv from the contrast enhanced CCTA. Single-source dual-energy scanning with GSI allows CAC quantification from low dose contrast enhanced CCTA by virtual iodine contrast subtraction.
-